Deduster 140

Type: ECOdust 1000 and 1100

Type nameECOdust 1000 deduster 1ECOdust 1100 deduster
Connection port diameter140 mm140 mm
Rated operating flow rate at 20 m/s1.108 m³/h1.108 m³/h
Negative pressure in feed air port at rated operating flow rate1.000 Pa2.400 Pa
Max. operating flow rate1.200 m³/h1.600 m³/h
Filter area (Filter: dust class M)7,1 m²7,1 m²
Air-to-cloth ratio at rated operating flow rate156 m³/m²/h156 m³/m²/h
Length of filter bags1.000 mm1.000 mm
Motor power/nominal current fan 400 V / 50 Hz1,5 kW/3,2 A2,2 kW/4,6 A
Sound level 1)67,0 dB (A)72,4 dB (A)
Number of chip bins11
Container volume170 l170 l
Relevant feed gas volume after EN 16770< 0,8 m³< 0,8 m³
Base area L × W790 × 790 mm790 × 790 mm
Total height2.430 mm2.430 mm
Weight170 kg175 kg

1) Noise value according to machine guidelines in the free field with a distance of 1.0 m at a height of 1.6 m. Measurement in accordance with ISO 11201, measured at rate operating flow rate without material transport. Measurement uncertainty K=±4dB.

Type: ECOdust 1000 and 1100 with increased filter area

Connection port diameterType nameECOdust 1000 dedusterEntstauber ECOdust 1100
Connection port diameter140 mm140 mm
Rated operating flow rate at 20 m/s1.108 m³/h1.108 m³/h
Negative pressure in feed air port at rated operating flow rate1.000 Pa2.400 Pa
Max. operating flow rate1.200 m³/h1.600 m³/h
File area in m² (filter: dust class M)9 m²9 m²
Air-to-cloth ratio at rated operating flow rate123 m³/m²/h123 m³/m²/h
Length of filter bags1.250 mm1.250 mm
Motor power/nominal current fan 400 V / 50 Hz1,5 kW/3,2 A2,2 kW/4,6 A
Sound level 1)67,0 dB (A)72,4 dB (A)
Number of chip bins11
Total chip volume in litres170 l170 l
Relevant feed gas volume after EN 16770< 0,8 m³< 0,8 m³
Base area L × W790 × 790 mm790 × 790 mm
Total height2.890 mm2.890 mm
Weight180 kg185 kg

1) Noise value according to machine guidelines in the free field with a distance of 1.0 m at a height of 1.6 m. Measurement in accordance with ISO 11201, measured at rate operating flow rate without material transport. Measurement uncertainty K=±4dB.